Nord-Lock Bolt Securing System

Vibration test diagram

The test diagram shows the bolt tension during vibration testing of some common fasteners. Most of the today commonly used locking devices show limited performance when exposed to vibration.


The vibration tests with NORD-LOCK show a positive result, although some of the initial tension is lost due to normal settlements. The locking function proves itself when the nut is being untightened with a wrench, a clear increase in tension is registered.


Even test report no. 375-130-91 carried out by the German TÜV confirms that after two million cycles the tension was maintained. An inspection of the washers showed that NORD-LOCK could be used safely.


Phones: (800) 638-1830 or (410) 358-3130 are available Monday-Friday 8:30 AM to 5:30 PM Eastern time.
Faxes: (800) 872-9329 or (410) 358-3142 & E-mail are available anytime.
Warehouse & showroom hours are Monday-Friday 10 AM to 5:30 PM.
[ To: Maryland Metrics home page ] [ To: Maryland Metrics Product Guide ] [ e-mail to Maryland Metrics ]
Please note that all Trademarks and Tradenames are the property of their respective owners.
copyright 2007 maryland metrics/nord-lock ab -- all rights reserved -- ver cc17g nnnnn.htm